Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
CAGE Information
Code | Company |
---|---|
09049 | CUSTOM CONTROL SENSORS INC. DBA CUST |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AASA | THREAD LENGTH | 0.310 INCHES MINIMUM ALL PRESSURE CONNECTION AND 0.380 INCHES MAXIMUM ALL PRESSURE CONNECTION |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
AXGY | MOUNTING METHOD | THREADED STUD |
ABKV | OUTSIDE DIAMETER | 0.112 INCHES NOMINAL ALL CONNECTIONS |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
ADAQ | BODY LENGTH | 1.660 INCHES MINIMUM AND 1.790 INCHES MAXIMUM |
CSCF | TERMINAL TYPE | WIRE LOOP |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
ABHP | OVERALL LENGTH | 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM |
CQJB | PROOF PRESSURE | 80.00 POUNDS PER SQUARE INCH GAGE |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTZL | PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL ALL CONNECTIONS |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CTYX | CONTACT STIMULUS RATING | 5.50 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 1.50 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
ADAV | OVERALL DIAMETER | 1.296 INCHES MINIMUM AND 1.328 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 40 ALL PRESSURE CONNECTION |
THSD | THREAD SERIES DESIGNATOR | UNC ALL PRESSURE CONNECTION |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.678 INCHES MINIMUM AND 0.698 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES ALL PRESSURE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
AAJD | THREAD CLASS | 2A ALL PRESSURE CONNECTION |