Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
44114 | BAE SYSTEMS LAND & ARMAMENTS L.P. DI |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBME | CUBIC MEASURE (NON-CORE) | 18.3 CUBIC INCHES |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 3.875 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING,5 SECONDARY WINDINGS |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAQ | BODY LENGTH | 2.218 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAT | BODY WIDTH | 2.125 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 6.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 18 TAB, SOLDER LUG |