Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE
Definition:
AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.
CAGE Information
Code | Company |
---|---|
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE |
ADAT | BODY WIDTH | 3.270 INCHES NOMINAL |
ADAQ | BODY LENGTH | 9.190 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE |
AHCG | MAXIMUM TEMP RISE | 35.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM AND 0.278 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.940 INCHES NOMINAL |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK INPUT |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK OUTPUT |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 4TH RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 1ST RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | ENCASED |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 5TH RADIO INTERFERENCE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK GROUND |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 6TH RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 6TH RADIO INTERFERENCE |
ABHP | OVERALL LENGTH | 9.800 INCHES MAXIMUM |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
PKWT | UNPACKAGED UNIT WEIGHT | 8.500 POUNDS |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AFGA | OPERATING TEMP RANGE | -55.0/+90.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 5TH RADIO INTERFERENCE |