Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
99699 | DRI RELAYS INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABMK | OVERALL WIDTH | 0.605 INCHES MAXIMUM |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.078 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABHP | OVERALL LENGTH | 1.320 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 600.0 OHMS MINIMUM SINGLE WINDING AND 900.0 OHMS MAXIMUM SINGLE WINDING |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
APNQ | ARC QUENCHING METHOD | AIR |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
ABTD | MOUNTING SLOT WIDTH | 0.175 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/9 GOVERNMENT SPECIFICATION |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |