Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
78277 SIGMA INSTRUMENTS INC

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 27.3 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
AKDX WINDING QUANTITY 1
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 5.0 MILLIAMPERES AC SINGLE WINDING
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.488 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 1.107 INCHES NOMINAL
ABMK OVERALL WIDTH 0.826 INCHES NOMINAL
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
APCN COIL QUANTITY 1
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE MOUNTING FACILITY
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
APNA WINDING DC RESISTANCE RATING 3.1 KILOHMS NOMINAL SINGLE WINDING
ABKW OVERALL HEIGHT 0.820 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY

Similar Parts

94498 , 94498 , 5945-00-810-5481 , 5945008105481 , 008105481