Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL

Definition:

AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.

CAGE Information

Code Company
07482 GENERAL ELECTRIC COMPANY DBA GE DIV

Federal Supply Class

Title

POWER AND HAND PUMPS

Inclusions:

Exclusions:

EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AHYX TOTAL HEAD 125.000 FEET
FEAT SPECIAL FEATURES 3.000 IN. INTAKE AND 2.000 IN. DISCHARGE FLANGE SIZE
FREQ FREQUENCY IN HERTZ 60.0
AHZF CENTRIFUGAL PUMP IMPELLER QUANTITY 1
ADZC ENVIRONMENTAL PROTECTION EXPLOSION PROOF
AHZS OPERATION RELATIONSHIP DESIGN SIMULTANEOUS
AHZV SUBMERSIBILITY (NON-CORE) NONSUBMERSIBLE
AKNA INCLOSURE TYPE FULLY INCLOSED
AAXS PRIME MOVER COOLING MEDIUM AIR
AENC PUMP QUANTITY 1
AHYZ OPERATING SPEED AT RATED CAPACITY 3450.0 REVOLUTIONS PER MINUTE
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AHZG CENTRIFUGAL PUMP IMPELLER SUCTION TYPE SINGLE
FAAZ PHASE THREE
AHZA PUMPING ELEMENT OPERATING POSITION HORIZONTAL
AMPS CURRENT RATING IN AMPS 12.1
AAYU INTAKE CONNECTION TYPE ROUND FLANGE
AAYT INTAKE CONNECTION QUANTITY 1
ELEC VOLTAGE IN VOLTS 460.0
AENK COOLING METHOD AIR TO AIR COOLED
AAXH PRIME MOVER QUANTITY 1
AAYW DISCHARGE CONNECTION TYPE ROUND FLANGE
AAYD STAGE QUANTITY 1
CSYL PRIME MOVER POWER RATING 7.5 HORSEPOWER
AAYV DISCHARGE CONNECTION QUANTITY 1
ACDC CURRENT TYPE AC
AHZE CENTRIFUGAL PUMP DESIGN MIXED FLOW
ZZZY REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS AS DIFFERENTIATED BY EXTRA LONG REFERENCE NUMBER
AHYV MAXIMUM DISCHARGE FLOW RATE 230.0 GALLONS PER MINUTE
ACKL MEDIA FOR WHICH DESIGNED NAPHTHA

Similar Parts

9493M62P01 , 9493M62P01 , 4320-01-362-5673 , 4320013625673 , 013625673