Part Number
Part Number:
NSN:
NIIN:
Item Name:
TEST STAND , HYDRAULIC SYSTEM COMP
Definition:
A CABINETLIKE ITEM USUALLY WITH A FRONT WORK AREA AND CONSISTING OF THE NECESSARY INSTRUMENTATION, INTEGRAL HYDRAULIC SYSTEM AND COMPONENT MOUNTING FACILITIES. DESIGNED TO PROVIDE THE HYDRAULIC PRESSURE FOR TESTING AND/OR CALIBRATING HYDRAULIC SYSTEM COMPONENTS, SUCH AS VALVES, ACTUATING CYLINDERS, PRESSURE REGULATORS, ACCUMULATORS, HOSE LINES, HAND AND/OR ENGINE DRIVEN PUMPS AND THE LIKE. MAY INCLUDE FACILITIES FOR FILLING AND CHECKING HYDRAULIC SYSTEMS FOR LEAKAGE AND PERFORMANCE. SEE ALSO PUMPING UNIT, HYDRAULIC.
CAGE Information
Code | Company |
---|---|
FA3E7 | INJECTION ET REGULATION MARINE |
Federal Supply Class
Title
MISCELLANEOUS MAINTENANCE AND RE
Inclusions:
INCLUDES PAINT SPRAYING EQUIPMENT.
Exclusions:
EXCLUDES HAND TOOLS (FSG 51).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
AGAV | END ITEM IDENTIFICATION | WEAPONS SYSTEM, NIMITZ CLASS CVN |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | NOT INCLUDED |
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | NOT INCLUDED |
AAYJ | HYDRAULIC FLUID FLOW RATE | NOT RATED |
ALBY | USAGE DESIGN | INDIVIDUAL HYDRAULIC UNITS |
BGST | PRESSURE RATING | 0.0 POUNDS PER SQUARE INCH MINIMUM AND 600.0 POUNDS PER SQUARE INCH MAXIMUM |
AMQY | INSTALLATION DESIGN | FIXED |
CHGQ | FILTERING SYSTEM | INCLUDED |
CHGR | PRESSURE/SUCTION HOSE | NOT INCLUDED |
FEAT | SPECIAL FEATURES | TEST STAND FOR GOVERNORS AND ACTUATORS |
ANCY | HORSEPOWER RATING | 3.0 |
ELEC | VOLTAGE IN VOLTS | 220.0 |
ACDC | CURRENT TYPE | AC |
AYJM | ACCUMULATOR | INCLUDED |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
FAAZ | PHASE | SINGLE |