Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
27777 | L-3 COMMUNICATIONS CORPORATION DBA W |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 72.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 12.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 85.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB, SOLDER LUG |
TEST | TEST DATA DOCUMENT | 13499-662-0194-010 DRAWING |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 14.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 12.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 48.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ADAT | BODY WIDTH | 2.750 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.063 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAQ | BODY LENGTH | 3.250 INCHES NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ACZB | FREQUENCY RATING | 1.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |