Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
09992 | ARRA INC |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKRZ | TERMINATION TYPE | CONNECTION COAXIAL |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +0.000/+18.000 GIGAHERTZ |
ARNH | OPERATING POSITION | ALL POSITIONS |
STYL | STYLE DESIGNATOR | COAXIAL MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | 50.0 NOMINAL |
BFMF | COOLING METHOD | SELF-COOLED |
AHUD | CONNECTOR END DESIGN | MALE |
ZZZV | FSC APPLICATION DATA | COMMUNICATION EQUIPMENT |
ABHP | OVERALL LENGTH | 1.300 INCHES NOMINAL |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
AFGQ | FREQUENCY RANGE RATING | +0.000/+18.000 GIGAHERTZ |
AJDB | POWER RATING | 5.000 WATTS AVERAGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
ADAV | OVERALL DIAMETER | 1.000 INCHES NOMINAL |