Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
F0228 | TURBOMECA |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 42.8 |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 42.8 |
AFZN | RECOVERED WALL THICKNESS | 0.048 INCHES NOMINAL |
HUES | COLOR | BLACK |
MATL | MATERIAL | RUBBER,POLYCHLOROPRENE,MIL-DTL-23053/1,CLASS 1 |
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 300.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND CORROSION RESISTANT AND WATER RESISTANT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 90.0 DEG CELSIUS |
AFZL | EXPANDED INSIDE DIAMETER | 0.500 INCHES MINIMUM |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
AFZM | RECOVERED INSIDE DIAMETER | 0.286 INCHES MAXIMUM |