Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , SENSITIVE
Definition:
A SWITCH WITH A QUICK-ACTING MECHANISM ACTUATED BY A HIGHLY DELICATE TACTILE CONTACT. INCLUDES MEMBRANE SWITCH. EXCLUDES SWITCH, FLEXIBLE; SWITCH, PRESSURE; AND SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
045F6 | REM PRODUCTS INC. |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFGK | ACTUATOR LENGTH | 1.500 INCHES NOMINAL |
AFGK | ACTUATOR LENGTH | 1.500 INCHES NOMINAL |
CXQQ | ACTUATOR MOVEMENT | 55.0 OVERTRAVEL DEGREES MINIMUM AND 44.0 PRETRAVEL DEGREES MAXIMUM AND 57.0 DIFFERENTIAL DEGREES MINIMUM |
CSJN | SWITCH ACTUATING FORCE | 24.0 OUNCES MINIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAQL | BODY STYLE | HOLE MOUNTED |
AFUT | ACTUATOR WIDTH | 0.255 INCHES MINIMUM AND 0.275 INCHES MAXIMUM |
AFUQ | ACTUATOR STYLE | NONADJUSTABLE ARM |
AFWD | HOUSING LENGTH | 2.812 INCHES NOMINAL |
CRRM | SWITCH RELEASE FORCE | 48.0 OUNCES MAXIMUM |
AFWC | HOUSING HEIGHT | 2.250 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT, STRATOLIFTER C-135; AIRCRAFT, (AC-130H, MC-130H, EC-130E, |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
AFUS | ACTUATOR HEIGHT | 0.675 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
AFWG | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.875 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 SCREW |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 400.000 MILLIAMPERES RESISTIVE DC AND 500.000 MILLIAMPERES INDUCTIVE AC |
AFWE | HOUSING WIDTH | 1.125 INCHES NOMINAL |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 28.0 DC |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
AFWH | CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH | 2.437 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |