Part Number
Part Number:
NSN:
NIIN:
Item Name:
CONTROLLER , MOTOR
Definition:
A DEVICE WHICH, IN ADDITION TO STARTING AND STOPPING A MOTOR, PERFORMS ONE OR MORE OF THE FOLLOWING FUNCTIONS: REVERSES THE ROTATION, SELECTS THE SPEED, AND/OR REGULATES THE SPEED OF A MOTOR. INCLUDES ITEMS OF THIS TYPE WHOSE DESIGN PROVIDES MEANS FOR OPERATION WITH A RHEOSTAT OR SPEED REGULATOR WHICH MAY BE INTEGRAL OR INCLUDED. ITEMS SUCH AS DRUM SWITCHES MAY BE INCLUDED. SEE ALSO STARTER, MOTOR.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQZF | CONTROL TYPE | REMOTE |
AQZF | CONTROL TYPE | REMOTE |
CBBL | FEATURES PROVIDED | ACCESSORY LOCATION EXTERNAL AND REVERSIBLE AND CIRCUIT PROTECTION FUSE |
AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
ANCQ | FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
ANCY | HORSEPOWER RATING | 20.000 |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
ANCP | VOLTAGE REDUCTION METHOD | RESISTOR |
ABMK | OVERALL WIDTH | 11.500 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 26.500 INCHES NOMINAL |
ANDX | AMBIENT TEMP | 50.000 DEG CELSIUS |
ALCD | USAGE DESIGN | U/W PUSH BUTTON SWITCH |
ANDE | ACTUATOR VOLTAGE | 230.0 DC |
ACUT | DIRECT CURRENT RATING IN AMPS | 100.0 |
ABKW | OVERALL HEIGHT | 30.000 INCHES NOMINAL |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 3 SIZE |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
AGUE | FUSE ACCOMMODATION QUANTITY | 1 |
AKPS | DUTY CYCLE | CONTINUOUS |
ALGC | MOUNTING CONFIGURATION | SIX 21/32 IN. DIA MTG HOLES ARRANGED IN 2 ROWS OF 3 HOLES EA WITH 27 IN. BETWEEN ROWS AND HOLES 11-1/4 IN. C TO C |
AFLW | ACTUATION METHOD | MAGNETIC |
ACYR | DC VOLTAGE RATING | 230.000 VOLTS NOMINAL |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
ANDW | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |