Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
13499 ROCKWELL COLLINS INC. DBA GOVERNMENT

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
ABMK OVERALL WIDTH 0.390 INCHES NOMINAL
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 40.0 MILLIAMPERES DC SINGLE WINDING
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.078 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES DC RESISTIVE LOAD
APCN COIL QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY
CBBL FEATURES PROVIDED POLARIZED
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABKW OVERALL HEIGHT 0.870 INCHES NOMINAL
ABHP OVERALL LENGTH 1.330 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
APNA WINDING DC RESISTANCE RATING 552.0 OHMS NOMINAL SINGLE WINDING
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY

Similar Parts