Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
97896 | HONEYWELL INTERNATIONAL INC DBA HONE |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTYX | CONTACT STIMULUS RATING | 145.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 140.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 120.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CQJX | NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE AND 400.0 FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
ASDB | WIDTH ACROSS FLATS | 0.940 INCHES NOMINAL |
AXGY | MOUNTING METHOD | THREADED BUSHING |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
ABPM | BODY DIAMETER | 0.580 INCHES MAXIMUM |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CSCF | TERMINAL TYPE | THREADED STUD |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
AASA | THREAD LENGTH | 0.760 INCHES NOMINAL SINGLE THREADED BUSHING |
ABHP | OVERALL LENGTH | 2.220 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
MEDA | MEDIA FOR WHICH DESIGNED | GAS, LIQUEFIED |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |