Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
97896 | HONEYWELL INTERNATIONAL INC DBA HONE |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CMLP | THREAD QUANTITY PER INCH | 12 SINGLE THREADED BUSHING |
ABHP | OVERALL LENGTH | 2.000 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | THREADED BUSHING |
STYL | STYLE DESIGNATOR | PLUG |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
ADAQ | BODY LENGTH | 0.970 INCHES NOMINAL |
CTYX | CONTACT STIMULUS RATING | 220.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
AAJD | THREAD CLASS | 3A SINGLE THREADED BUSHING |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
ASDB | WIDTH ACROSS FLATS | 1.380 INCHES NOMINAL |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
THSD | THREAD SERIES DESIGNATOR | UN SINGLE THREADED BUSHING |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CQJX | NOMINAL THREAD SIZE | 1.063 INCHES SINGLE THREADED BUSHING |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 340.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CBBL | FEATURES PROVIDED | ELECTRICAL BOX CONNECTOR |