Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.750 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.125 INCHES |
MATT | MATERIAL | PLASTIC BOARD |
CRZR | FEEDTHRU TERMINAL QUANTITY | 5 SINGLE COMBINATION |
ABCS | TERMINAL ROW QUANTITY | 1 |
ABGP | BOARD OVERALL WIDTH | 1.250 INCHES |
CWLN | TERMINAL DESIGN | LATERAL FEEDTHRU |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 8.0 |
ABGN | BOARD OVERALL LENGTH | 3.031 INCHES |
AMPS | CURRENT RATING IN AMPS | 85.0 |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.875 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
CQCW | FEEDTHRU CONNECTION END TYPE | 611 15TH MATERIAL RESPONSE BOTH ENDS |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.578 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAMA | MOUNTING HOLE DIAMETER | 0.180 INCHES |
AAQL | BODY STYLE | PRESSURE-CONTACT-RIGID |
CQCW | FEEDTHRU CONNECTION END TYPE | 611 FOURTH COMBINATION BOTH ENDS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.625 INCHES |