CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
D2416 THALES (VORM. THOMSON-CSF ELEKTRONIK

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 AC ALL LOCATIONS
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR ISO S
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
CQJX NOMINAL THREAD SIZE 3.5 MILLIMETERS
AKPX POLE QUANTITY 2
AFJN FRAGILITY FACTOR MODERATELY RUGGED
PKWT UNPACKAGED UNIT WEIGHT 7.400 OUNCES
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 6.000 MINIMUM ALL LOCATIONS AND 60.000 MAXIMUM ALL LOCATIONS
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 60.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 6.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 0.400 MINIMUM AT 400 PCT ALL LOCATIONS AND 1.500 MAXIMUM AT 400 PCT ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES NOMINAL
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CQQR THREAD PITCH IN MILLIMETERS ANY ACCEPTABLE
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAT BODY WIDTH 1.530 INCHES MAXIMUM
CRTK SWITCH TERMINAL TYPE TURRET
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
CTTC THREAD TOLERANCE CLASS ANY ACCEPTABLE
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
ADAQ BODY LENGTH 2.490 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL