Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
F6481 |
THALES |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.605 INCHES MAXIMUM |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS SINGLE LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.380 INCHES MAXIMUM |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC SINGLE LOCATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
CRTK |
SWITCH TERMINAL TYPE |
EYELET |
PKWT |
UNPACKAGED UNIT WEIGHT |
2.100 OUNCES |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
120.0 AC AND 50.0 DC |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE HOOK |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
0.5 AC AND 0.5 DC |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES AC SINGLE LOCATION |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
ADAQ |
BODY LENGTH |
1.500 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
METAL |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
CMLP |
THREAD QUANTITY PER INCH |
32 |
ADAT |
BODY WIDTH |
0.625 INCHES MAXIMUM |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SINGLE LOCATION |
Similar Parts