Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
88236 | COMMUNICATIONS & POWER INDUSTRIES LL |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1B |
ABHP | OVERALL LENGTH | 1.620 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.430 INCHES NOMINAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 24.0 DC |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.460 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 1.2 MILLIAMPERES DC SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 13.8 KILOHMS NOMINAL SINGLE WINDING |