Part Number
Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
63857 | WARREN PUMPS LLC |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHYZ | OPERATING SPEED AT RATED CAPACITY | 3550.0 REVOLUTIONS PER MINUTE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
AHZV | SUBMERSIBILITY (NON-CORE) | NONSUBMERSIBLE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AMPS | CURRENT RATING IN AMPS | 3.0 |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AENC | PUMP QUANTITY | 1 |
AHYW | DISCHARGE PRESSURE | 50.0 POUNDS PER SQUARE INCH GAGE |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
CSYL | PRIME MOVER POWER RATING | 40.0 HORSEPOWER |
FAAZ | PHASE | THREE |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 750.0 GALLONS PER MINUTE |
AHZA | PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYD | STAGE QUANTITY | 1 |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
ACDC | CURRENT TYPE | AC |
AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
ELEC | VOLTAGE IN VOLTS | 440.0 |