RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
18876 U S ARMY AVIATION AND MISSILE COMMAN

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE HOOK ALL FUNCTIONS
CQYJ MOUNTING FACILITY PATTERN DIAGONAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTCN MINIMUM DIFFERENTIAL ELECTRICAL OPERATING RATING 22.5 MILLIAMPERES
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 26.0 DC
ABMK OVERALL WIDTH 0.412 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 40.0 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 1.349 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
ABKW OVERALL HEIGHT 1.140 INCHES NOMINAL
APNP DUTY TYPE CONTINUOUS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
APNA WINDING DC RESISTANCE RATING 200.0 OHMS NOMINAL SINGLE WINDING