Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHTA | FLANGE OUTSIDE HEIGHT | 5.454 INCHES MAXIMUM SECOND FLANGE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION (NON-CORE) | QQ-A-250/11,T6 FED SPEC SINGLE MATERIAL RESPONSE ALL FLANGE |
AHSF | FLANGE QUANTITY | 2 |
CTCJ | FLANGE STYLE | CONTACT TYPE ALL FLANGES |
CRFH | WAVEGUIDE INSIDE WIDTH | 6.500 INCHES NOMINAL |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 3.610 INCHES NOMINAL |
AHSZ | FLANGE OUTSIDE WIDTH | 8.631 INCHES MINIMUM ALL FLANGES AND 8.745 INCHES MAXIMUM ALL FLANGES |
CRLB | WAVEGUIDE INSIDE HEIGHT | 3.250 INCHES NOMINAL |
AHSX | FLANGE INSIDE WIDTH | 6.490 INCHES MINIMUM ALL FLANGES AND 6.510 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 5.422 INCHES MINIMUM FIRST FLANGE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 10 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
MATT | MATERIAL | ALUMINUM ALLOY 6061 ALL FLANGE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
CQGM | MAXIMUM OPERATING PRESSURE | 25.0 POUNDS PER SQUARE INCH GAGE |
ZZZV | FSC APPLICATION DATA | ANTENNA RECEIVER TRANSMITTER GROUP MISSILE TRACKING |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 6.860 INCHES NOMINAL |
AHSY | FLANGE INSIDE HEIGHT | 3.240 INCHES MINIMUM ALL FLANGES AND 3.260 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.980 INCHES MINIMUM ALL FLANGES AND 1.020 INCHES MAXIMUM ALL FLANGES |