Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | INTERMITTENT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.370 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | TYPE F-1-B-AC,F-2-B-AC,F-3-B-AC |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 117.0 AC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD |
ABMK | OVERALL WIDTH | 1.750 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1A AND 1A |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |