Item Name:
TRANSFORMER , POWER AUTOTRANSFORME

Definition:

A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.

CAGE Information

Code Company
93217 GENERAL ELECTRIC CO PRODUCTS SERVICE

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABKW OVERALL HEIGHT 3.500 INCHES NOMINAL
ABKW OVERALL HEIGHT 3.500 INCHES NOMINAL
FEAT SPECIAL FEATURES 50 HERTZ VOLTAGE RANGE OF 189 VOLTS TO 260 VOLTS INPUT AND 102 VOLTSTO 118 VOLTS OUTPUT,60 HERTZ VOLTAGE RANGE OF 208 VOLTS TO 289 VOLTSINPUT AND 111 VOLTS TO 128 VOLTS OUTPUT
AKNA INCLOSURE TYPE FULLY INCLOSED
CRBZ WINDING OPERATING CURRENT 6.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 102.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 128.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT
AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MAXIMUM SINGLE COMPONENT
AKPV MOUNTING FACILITY QUANTITY 3 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 189.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY INPUT AND 289.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY INPUT
ABMK OVERALL WIDTH 3.875 INCHES NOMINAL
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ABHP OVERALL LENGTH 6.000 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
TTQY TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG

Similar Parts