Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
55947 SQUARE D CO SORGEL MFG PLANT

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
ADAT BODY WIDTH 11.750 INCHES NOMINAL
ABTB MOUNTING HOLE DIAMETER 0.562 INCHES NOMINAL 2ND GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
CWJS WINDING OPERATING VOLTAGE 450.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 416.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 461.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 405.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 438.75 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 427.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 472.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
AXGY MOUNTING METHOD UNTHREADED HOLE 2ND GROUP
AKPV MOUNTING FACILITY QUANTITY 1 2ND GROUP
CWJS WINDING OPERATING VOLTAGE 111.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 109.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 123.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 114.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 126.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 WIRE LEAD
ABTD MOUNTING SLOT WIDTH 0.312 INCHES NOMINAL 1ST GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAQ BODY LENGTH 9.750 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 11.1 AMPERES NOMINAL B SINGLE COMPONENT SINGLE PRIMARY
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 4.750 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP
ABKW OVERALL HEIGHT 14.750 INCHES NOMINAL
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 130.000 POUNDS
AKPV MOUNTING FACILITY QUANTITY 2 1ST GROUP
ACZF MAXIMUM TRANSFORMER POWER RATING 5.0 KILOVOLT-AMPERE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AXGY MOUNTING METHOD SLOT 1ST GROUP
CRBZ WINDING OPERATING CURRENT 41.7 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

A-612377-A-3 , A612377A3 , 5950-01-312-6741 , 5950013126741 , 013126741