CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
58536 FEDERAL COMMERCIAL ITEM DESCRIPTION

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
ADAT BODY WIDTH 1.875 INCHES NOMINAL
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.406 INCHES NOMINAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
AFJN FRAGILITY FACTOR MODERATELY RUGGED
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CQJX NOMINAL THREAD SIZE 0.190 INCHES
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.625 INCHES MAXIMUM
ZZZK SPECIFICATION/STANDARD DATA MIL-C-13516/4 GOVERNMENT SPECIFICATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.063 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 575.0 DC SINGLE LOCATION
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 8.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRQ RESET METHOD MANUAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 105.0 AMPERES DC SINGLE LOCATION
THSD THREAD SERIES DESIGNATOR UNF
ABHP OVERALL LENGTH 3.227 INCHES NOMINAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
TEST TEST DATA DOCUMENT MIL-C-13516 SPECIFICATION
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 28.0 DC SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS PROOF AND SHOCK RESISTANT AND SALT SPRAY PROOF AND VIBRATION RESISTANT
PKWT UNPACKAGED UNIT WEIGHT 5.000 OUNCES
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION