Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
58536 | FEDERAL COMMERCIAL ITEM DESCRIPTION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQCW | FEEDTHRU CONNECTION END TYPE | 600 15TH MATERIAL RESPONSE BOTH ENDS |
ABGQ | BOARD OVERALL HEIGHT | 1.125 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.000 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 2.2 |
ABCS | TERMINAL ROW QUANTITY | 1 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-B728,CLASS B FED SPEC SINGLE MATERIAL RESPONSE TERMINALS |
CRZR | FEEDTHRU TERMINAL QUANTITY | 14 SINGLE COMBINATION |
AMPS | CURRENT RATING IN AMPS | 40.0 |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.313 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 600 FOURTH COMBINATION BOTH ENDS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE MAI-60 MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.250 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.625 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
CWLN | TERMINAL DESIGN | VERTICAL FEEDTHRU |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.000 INCHES |
AAQX | MOUNTING SLOT WIDTH | 0.173 INCHES |
MATT | MATERIAL | COPPER ALLOY 670 TERMINALS |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
MATT | MATERIAL | PLASTIC POLYESTER BOARD AND GLASS FIBER BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
ABGS | BASE THICKNESS | 0.500 INCHES |
ABGN | BOARD OVERALL LENGTH | 6.500 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |