Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
58536 | FEDERAL COMMERCIAL ITEM DESCRIPTION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.421 INCHES |
MATT | MATERIAL | PLASTIC BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
ABGQ | BOARD OVERALL HEIGHT | 0.578 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-N-290,CLASS 1,TYPE 8 FED SPEC SINGLE TREATMENT RESPONSE TERMINALS |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.421 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.141 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.578 INCHES |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 13 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 13 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
AMPS | CURRENT RATING IN AMPS | 20.0 |
ABGS | BASE THICKNESS | 0.391 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABGP | BOARD OVERALL WIDTH | 1.125 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.352 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAMA | MOUNTING HOLE DIAMETER | 0.203 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
ABGN | BOARD OVERALL LENGTH | 6.469 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3400.0 |
AAQL | BODY STYLE | BARRIER TYPE |