Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
00144 | ADC TELECOMMUNICATIONS INC. DIV ADC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 5.560 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ACZB | FREQUENCY RATING | 54.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
FEAT | SPECIAL FEATURES | TWO TERMINALS CONNECTED TO END TERMINALS IN SECONDARY WINDING BECAUSE OF HIGH CURRENTS |
CWJS | WINDING OPERATING VOLTAGE | 109.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 126.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 132.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 18.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 6.60 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ABHP | OVERALL LENGTH | 4.310 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.690 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 11 SOLDER STUD |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |