Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
0D0D0 | BAE SYSTEMS INFORMATION AND ELECTRON |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TEST | TEST DATA DOCUMENT | 81349-MIL-STD-202 STANDARD |
AJDB | POWER RATING | 100.000 WATTS AVERAGE |
ARNH | OPERATING POSITION | ALL POSITIONS |
BFMF | COOLING METHOD | SELF-COOLED |
AFGQ | FREQUENCY RANGE RATING | +0.960/+1.215 GIGAHERTZ |
ABHP | OVERALL LENGTH | 1.375 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.335 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RF CONNECTOR, SURFACE MOUNTED |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | -55.0 AND 85.0 |
ACYW | IMPEDANCE RATING IN OHMS | 45.0 MINIMUM AND 55.0 MAXIMUM |
ADAQ | BODY LENGTH | 1.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.822 INCHES NOMINAL |
AKRZ | TERMINATION TYPE | BINDING POST |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 AND 1.00 |