Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , DIRECT CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM A DIRECT CURRENT SOURCE. EXCLUDES MOTOR, ENGINE STARTER, ELECTRICAL. SEE ALSO MOTOR, CONTROL.
CAGE Information
Code | Company |
---|---|
95402 | ELECTRIC BOAT CORP DBA ELECTRO DYNAM |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | FLANGE |
ABWV | SHAFT DIAMETER | 1.8050 INCHES NOMINAL SINGLE END |
AKCT | SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END |
CWFQ | MOUNTING FACILITY CIRCLE DIAMETER | 14.875 INCHES |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 250.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
AAJU | OVERALL LENGTH | 58.938 INCHES |
CWHZ | SHAFT END CHARACTERISTIC | A2 FIRST STYLE SINGLE END AND A29 SECOND STYLE SINGLE END |
AXCP | WINDING TYPE | SHUNT WOUND W/COMMUTATION POLES-COMPENSATING WINDINGS |
CWGL | CURRENT RATING IN AMPS | 440.000 SINGLE INPUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | VERTICAL MOUNTING POSITION AND HORIZONTAL MOUNTING POSITION |
CWDY | TEMP RATING | 60.0 AMBIENT DEG CELSIUS AND 50.0 OPERATING DEG CELSIUS |
AKPS | DUTY CYCLE | CONTINUOUS |
BFMF | COOLING METHOD | NATURAL CONVECTION VENTILATED |
ABND | TAPER LENGTH | 2.6250 INCHES NOMINAL SINGLE END |
BKPB | CURRENT RATING METHOD | LOAD |
AAJT | OVERALL HEIGHT | 29.125 INCHES |
AAJV | OVERALL WIDTH | 27.750 INCHES |
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.400 INCHES SINGLE END |