Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code |
Company |
05584 |
AUTODYNE MANUFACTURING CO. INC. |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
FEAT |
SPECIAL FEATURES |
SECONDARY CURRENTS ARE LISTED AS DC |
CRBZ |
WINDING OPERATING CURRENT |
5.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
BPLC |
WINDING FUNCTION AND QUANTITY |
2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
ADAU |
BODY HEIGHT |
3.745 INCHES MINIMUM AND 3.755 INCHES MAXIMUM |
ADAT |
BODY WIDTH |
2.305 INCHES MINIMUM AND 2.315 INCHES MAXIMUM |
AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
CRBZ |
WINDING OPERATING CURRENT |
60.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
TTQY |
TERMINAL TYPE AND QUANTITY |
10 WIRE HOOK |
PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
38.000 OUNCES |
CRBZ |
WINDING OPERATING CURRENT |
200.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
ADAQ |
BODY LENGTH |
2.685 INCHES MINIMUM AND 2.695 INCHES MAXIMUM |
ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
Similar Parts