Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
CAGE Information
Code | Company |
---|---|
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 10 SOLDERLESS LUG |
TTQY | TERMINAL TYPE AND QUANTITY | 10 SOLDERLESS LUG |
ASKA | COMPONENT NAME AND QUANTITY | 1 COIL AND 1 TRANSFORMER |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAQ | BODY LENGTH | 7.000 INCHES MAXIMUM |
ACYV | INDUCTANCE RATING | 10.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING AND 50.00 MILLIHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.407 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.469 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ADAU | BODY HEIGHT | 4.562 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 450.0 HERTZ MINIMUM SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 28.000 POUNDS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 11.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
ADAT | BODY WIDTH | 4.188 INCHES MAXIMUM |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 SINGLE COMPONENT SINGLE WINDING |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER SINGLE COMPONENT SINGLE WINDING AND 11.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |