TOWER
Definition:
AN OPEN FRAME STRUCTURE WHICH IS HIGH IN PROPORTION TO ITS LATERAL DIMENSIONS AND HAS MORE THAN A SINGLE FOOTING OR MOUNTING BASE. IT IS NORMALLY USED TO SUPPORT SUCH ITEMS AS ANTENNAS, LOUDSPEAKERS, WATER TANKS, CABINS, AND THE LIKE, WHICH MAY BE FURNISHED. EXCLUDES TOWER, DOUBLE STRUCTURE, SURVEYING AND MAST.
CAGE Information
Code | Company |
---|---|
80058 | JOINT ELECTRONICS TYPE DESIGNATION S |
Federal Supply Class
Title
PREFABRICATED TOWER STRUCTURES
Inclusions:
INCLUDES POWER TRANSMISSION TOWERS; RADAR TOWERS; SEARCHLIGHT TOWERS; CONTROL TOWERS; PREFABRICATED TOWER COMPONENTS, SUCH AS ANCHOR RAILS, TIE RODS, BRACES, STEPS, GUY ASSEMBLIES; SPECIALIZED TOWER HARDWARE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HGTH | HEIGHT | 25.000 FEET NOMINAL |
HGTH | HEIGHT | 25.000 FEET NOMINAL |
CCMG | SUPPORTED ITEM NAME | ANTENNA |
MATL | MATERIAL | STEEL |
ALPM | ASSEMBLY FORM | KNOCKED-DOWN |
CCML | REST PLATFORM QUANTITY | 0 |
CCMK | CLIMBING FACILITY | LADDER AND STAIRS |
SURF | SURFACE TREATMENT | GALVANIZED OR PAINT |
AJQL | TOP DIAMETER | 20.000 FEET NOMINAL |
ACDN | BOTTOM DIAMETER | 20.000 FEET |
CCMY | ELEVATING FACILITY | DERRICK OR HOIST |
SHPE | SHAPE | HEXAGON |
CCMM | CABIN | NOT INCLUDED |
AXQD | CAPACITY | 2000.0 POUNDS |
CCMX | LIGHTNING ROD | INCLUDED |
AERK | GROUNDING PROVISION | INCLUDED |
FEAT | SPECIAL FEATURES | ZDESIGNED FOR ARTIC USE,FRAMEWORKOF STRUCTURE COMPLETELY ENCLOSED BY WALL SHEET STEEL W/INSULATION,2 INTERNAL FLOORS,2ND FLOOR HOUSES ANTENNA EQMT,WILL WITHSTAND WIND VELOCITY OF 132KNOTS,SELF SUPPORTING,MOUNTED ON CONCRETE FOUNDATION |