A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
80103 | VEECO INSTRUMENTS INC LAMBDA DIV |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 3.500 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.500 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL SINGLE GROUP |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 3.219 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 40.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 24.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 132.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQKH | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE BASE OF AN ISOSCELES TRIANGLE | 3.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
AKPV | MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.578 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.750 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |