Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION
ADAT BODY WIDTH 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
AAQL BODY STYLE SINGLE POLE TYPE
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
ADAQ BODY LENGTH 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 1.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION RESISTANT AND HERMETICALLY SEALED
AAJE THREAD PITCH DIAMETERS +0.3503/+0.3537 INCHES
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
TTQY TERMINAL TYPE AND QUANTITY 2 WIRE HOOK
ABXD BUSHING LENGTH 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC SINGLE LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
ADTV CASE MATERIAL METAL
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 750.0 MILLIAMPERES AC SINGLE LOCATION
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION

Similar Parts