Part Number
Part Number:
NSN:
NIIN:
Item Name:
AIR CONDITIONER
Definition:
A SELF-CONTAINED UNIT DESIGNED TO PERFORM THE FUNCTIONS OF COOLING, CIRCULATING, FILTERING, DEHUMIDIFYING OR OTHERWISE PROCESSING OF AIR. IT MAY ALSO BE EQUIPPED TO PERFORM THE ADDITIONAL FUNCTIONS OF HEATING OR HUMIDIFYING. IT MAY BE THE AIR CYCLE TYPE USED IN AIRCRAFT OR THE VAPOR CYCLE TYPE APPLICABLE TO GROUND OR AEROSPACE EQUIPMENT. EXCLUDES ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.
CAGE Information
Code | Company |
---|---|
81348 | FEDERAL SPECIFICATIONS PROMULGATED B |
Federal Supply Class
Title
AIR CONDITIONING EQUIPMENT
Inclusions:
INCLUDES STORE TYPE UNITS; WINDOW AND ROOM TYPE UNITS; MARINE, AND VEHICULAR AIR CONDITIONING UNITS; AIR CONDITIONING PLANTS AND SYSTEMS.
Exclusions:
EXCLUDES AIR CONDITIONING COMPONENTS (FSC 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;1ST MOTOT-5.000 HP,2ND MOTOR-1.600 HP,3RD MOTOR-6.000 HP;ACCESSORIES-NOT INCL. |
AZSH | NOMINAL HEATING CAPACITY | 2010.0 CUBIC FEET PER MINUTE |
CYKM | HEATING CAPACITY IN BTU PER HOUR | 47100.0 NOMINAL |
AMSE | VOLTAGE RATING | 208.0 VOLTS NOMINAL |
AAXX | MOUNTING TYPE | FLOOR |
CYGG | CABINET MATERIAL | ALUMINUM-COPPER FREE |
ALCD | USAGE DESIGN | COMPRESSOR,CONDENSER,EVAPORATOR |
AZSF | NOMINAL COOLING CAPACITY | 2010.0 CUBIC FEET PER MINUTE |
FAAZ | PHASE | THREE |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL |
ARNA | COOLANT TYPE | FREON-22 |
SFTT | SURFACE TREATMENT | ENAMEL |
AZAD | CONDENSER COOLING TYPE | AIR |
AWLX | ELECTRIC MOTOR QUANTITY | 3 |
ACDC | CURRENT TYPE | AC |
ZZZT | NONDEFINITIVE SPEC/STD DATA | A/E 32C-27 TYPE |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
AZSD | COMPRESSOR UNIT TYPE | SEMIHERMETIC |
CYJE | COOLING CAPACITY IN BTU PER HOUR | 60000.0 NOMINAL |