Part Number
Definition:
A CABINETLIKE ITEM USUALLY WITH A FRONT WORK AREA AND CONSISTING OF THE NECESSARY INSTRUMENTATION, INTEGRAL HYDRAULIC SYSTEM AND COMPONENT MOUNTING FACILITIES. DESIGNED TO PROVIDE THE HYDRAULIC PRESSURE FOR TESTING AND/OR CALIBRATING HYDRAULIC SYSTEM COMPONENTS, SUCH AS VALVES, ACTUATING CYLINDERS, PRESSURE REGULATORS, ACCUMULATORS, HOSE LINES, HAND AND/OR ENGINE DRIVEN PUMPS AND THE LIKE. MAY INCLUDE FACILITIES FOR FILLING AND CHECKING HYDRAULIC SYSTEMS FOR LEAKAGE AND PERFORMANCE. SEE ALSO PUMPING UNIT, HYDRAULIC.
CAGE Information
Code | Company |
---|---|
80049 | DEPARTMENT OF THE AIR FORCE |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AYJM | ACCUMULATOR | NOT INCLUDED |
AYJM | ACCUMULATOR | NOT INCLUDED |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM |
FREQ | FREQUENCY IN HERTZ | 60.0 |
FCLS | FUNCTIONAL CLASSIFICATION | AA-9.2 |
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | INCLUDED |
BGST | PRESSURE RATING | 6000.0 POUNDS PER SQUARE INCH NOMINAL |
ANCY | HORSEPOWER RATING | 40.0 |
CGYL | FLOW CAPACITY RATING | 30.0 GALLONS PER MINUTE |
CHGP | CIRCUIT PRESSURE RATING | 50.0 POUNDS PER SQUARE INCH NOMINAL |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | INCLUDED |
ATPR | MAXIMUM SPEED RATING IN RPM | 3600.0 |
RDAL | REFERENCE DATA AND LITERATURE | T.O.33D2-5-39-1 |
FTLD | FUNCTIONAL DESCRIPTION | USED TO TEST ACFT HYDRAULIC SYSTEMS/COMPONENTS WITHOUT OPERATING THE ACFT ENGINE OR REMOVING THE COMPONENTS FROM THE ACFT |
FAAZ | PHASE | THREE |
AMQY | INSTALLATION DESIGN | PORTABLE |
CHGR | PRESSURE/SUCTION HOSE | INCLUDED |
CHGN | SUBCIRCUIT QUANTITY AND MAXIMUM OPERATING PRESSURE | ONE 50.0 PSI |
CHGQ | FILTERING SYSTEM | INCLUDED |
BJDW | MAXIMUM OPERATING PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
APBT | CIRCUIT TYPE | BOOSTER CYLINDER |
ZZZV | FSC APPLICATION DATA | F-15,F/RF-4 ACFT AGE |
AAYJ | HYDRAULIC FLUID FLOW RATE | 60.0 GALLONS PER MINUTE |
ACDC | CURRENT TYPE | AC |
TMDN | TYPE/MODEL DESIGNATION | A/M27T-2 |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
AKCV | DRIVE TYPE | ELECTRIC MOTOR |
ELEC | VOLTAGE IN VOLTS | 440.0 |