Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
81205 |
THE BOEING COMPANY DBA BOEING DIV DE |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CQJX |
NOMINAL THREAD SIZE |
0.4688 INCHES |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
7.000 MAXIMUM AT 400 PCT SINGLE LOCATION AND 15.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.000 MINIMUM AT 600 PCT SINGLE LOCATION AND 2.000 MINIMUM AT 400 PCT SINGLE LOCATION AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 3.500 MAXIMUM AT 600 PCT SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.860 INCHES MAXIMUM |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC SINGLE LOCATION AND 15.0 AMPERES DC SINGLE LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.704 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2800.0 AC SINGLE LOCATION AND 4800.0 DC SINGLE LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB W/SCREW |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
AGAV |
END ITEM IDENTIFICATION |
BOEING B757 AIRCRAFT |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
PKWT |
UNPACKAGED UNIT WEIGHT |
0.150 POUNDS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
200.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.250 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
FEAT |
SPECIAL FEATURES |
THREAD CLASS 2A; BARRIER EXTENDS FROM BOTTOM OF BREAKER 0.500 INCH, LENGTH IS 1.218 INCHES NOMINAL, AND THICKNESS IS 0.031 INCH NOMINAL |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
ADAT |
BODY WIDTH |
0.750 INCHES MAXIMUM |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
ADAQ |
BODY LENGTH |
1.152 INCHES MAXIMUM |