Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
82647 |
SENSATA TECHNOLOGIES INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
ABKW |
OVERALL HEIGHT |
1.281 INCHES NOMINAL |
ABKW |
OVERALL HEIGHT |
1.281 INCHES NOMINAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION |
ABHP |
OVERALL LENGTH |
2.000 INCHES NOMINAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
120.0 SINGLE LOCATION |
CPRQ |
RESET METHOD |
AUTOMATIC |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
600.0 AC SINGLE LOCATION AND 600.0 DC SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
100.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 7.500 NOMINAL AT 200 PCT SINGLE LOCATION AND 1.900 NOMINAL AT 300 PCT SINGLE LOCATION |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.188 INCHES NOMINAL |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCKPROOF AND VIBRATIONPROOF |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
30.0 AMPERES AC SINGLE LOCATION AND 30.0 AMPERES DC SINGLE LOCATION |
ABMK |
OVERALL WIDTH |
1.188 INCHES NOMINAL |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE |
Similar Parts