Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
09017 EDO

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ADAT BODY WIDTH 1.281 INCHES MAXIMUM
PKWT UNPACKAGED UNIT WEIGHT 3.600 OUNCES
ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM
AKPX POLE QUANTITY 2
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 50.0 DC ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM
CPSM INTERNAL TRIP RELEASE CONFIGURATION SHUNT TRIP ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.060 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 150.0 MILLIAMPERES DC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AAJE THREAD PITCH DIAMETERS +0.3503/+0.3537 INCHES
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
AEFS NONTURN DEVICE DIAMETER 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM
CPRQ RESET METHOD MANUAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.407 INCHES MINIMUM AND 0.469 INCHES MAXIMUM
AEFP NONTURN DEVICE RADIUS 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
ADTV CASE MATERIAL METAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 DC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
ADAQ BODY LENGTH 1.562 INCHES MAXIMUM
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CMLP THREAD QUANTITY PER INCH 32
TTQY TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
AEFN NONTURN DEVICE LOCATION AT 3 OCLOCK AND AT 9 OCLOCK
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS

Similar Parts

CB5323 , CB5323 , 5925-00-954-1724 , 5925009541724 , 009541724