Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
81482 | PAGE CHESTER LTD. DBA COOPERATIVE IN |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | NATURAL |
ARJD | DESIGN FORM | FULL ROUND |
CQBC | MINIMUM TENSILE STRENGTH | 2500 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 5.0 |
FEAT | SPECIAL FEATURES | 8 CONVOLUTIONS PER INCH; TWO 1/8 INCH DIAMETER DRAIN HOLES; DIAMETRICALLY OPPOSED, EVERY 6 INCHES IN LENGTH OF THE TUBE/SLEEVE |
ABJH | TEMP RATING | -95.0 DEG FAHRENHEIT AND 500.0 DEG FAHRENHEIT |
AAGT | WALL THICKNESS | 0.024 INCHES MINIMUM AND 0.034 INCHES MAXIMUM |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TUBE-CONVOLUTED, TFE-FLOUROCARBON |
MATL | MATERIAL | PLASTIC, POLYTETRAFLUOROETHYLENE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 15000.0 |
AGAV | END ITEM IDENTIFICATION | 1560-01-461-7434 |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
AARX | INSIDE DIAMETER | 0.730 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |