Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
THERMOSTAT , FLOW CONTROL

Definition:

AN AUTOMATIC REGULATING DEVICE WHICH CONTROLS THE FLOW OF FLUIDS OR GASES BY ACTUATING A VALVE OR SHUTTER FOR HEATING OR COOLING PURPOSES. MAY BE ADJUSTABLE, OR SET TO OPERATE AT A DEFINITE PRESSURE. EXCLUDES CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; AND SWITCH, THERMOSTATIC.

CAGE Information

Code Company
75418 KYSOR INDUSTRIAL CORP

Federal Supply Class

Title

PRESSURE, TEMPERATURE, AND HUMID

Inclusions:

INCLUDES THERMOMETERS, INCLUDING ENGINE THERMOMETERS; PRESSURE GAGES; THERMOCOUPLE LEADS; RESISTANCE BULBS.

Exclusions:

EXCLUDES CLINICAL THEROMETERS; (FSC 6515); THERMOSTATIC AND DIFFERENTIAL PRESSURE SWITCHES (FSC 5930); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADQU FLOW CONTROL DEVICE POSITIVE OPEN OR CLOSED NEEDLE VALVE
ADQU FLOW CONTROL DEVICE POSITIVE OPEN OR CLOSED NEEDLE VALVE
AWTQ DISTANCE ACROSS FLATS 1.875 INCHES NOMINAL
AWTM OPENING TEMP RATING 175.0 DEG FAHRENHEIT NOMINAL
ABKW OVERALL HEIGHT 5.812 INCHES NOMINAL
AWTN OPERATING TEMP RATING 175.0 DEG FAHRENHEIT NOMINAL
AWPA THERMOSTAT TYPE SOLID EXPANSION
AAJF THREAD DIRECTION RIGHT-HAND
THDS THREAD SIZE AND SERIES/TYPE DESIGNATOR 1/2-14 NPT
ADJH MOUNTING METHOD THREADED
ZZZV FSC APPLICATION DATA THERMOSTAT,FLOW CONTROL,EXCEPT ENGINE
ALCD USAGE DESIGN CONTROL FLUID TEMP
AWTP SPRING OPERATED PRESSURE RELIEF NOT PROVIDED
AMSD VALVE TRAVEL DISTANCE 0.006 INCHES NOMINAL

Similar Parts

D24000-175 , D24000175 , 6685-00-395-3272 , 6685003953272 , 003953272