Part Number
Part Number:
NSN:
NIIN:
Item Name:
ALARM , CHEMICAL AGENT , AUTOMATIC
Definition:
A DEVICE WHICH DETECTS THE PRESENCE OF CHEMICAL AGENTS (WAR GASES) AND SOUNDS AN ALARM, AND/OR LIGHTS A WARNING LIGHT OF DISTINCTIVE COLOR. EXCLUDES ALARM, GAS, AUTOMATIC.
CAGE Information
Code | Company |
---|---|
81361 | EDGEWOOD CHEMICAL BIOLOGICAL CENTER |
Federal Supply Class
Title
HAZARD-DETECTING INSTRUMENTS AND
Inclusions:
INCLUDES RADIAC EQUIPMENT; GAS DETECTING EQUIPMENT; LAND MINE DETECTING EQUIPMENT.
Exclusions:
EXCLUDES MANUAL GAS ALARMS (FSC 6350).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ALXZ | SPECIFIC USAGE DESIGN | SPECIFIC USAGE DESIGN SAMPLES AIR CONTINOUSLY,WHICH IS AUTOMATICALLY HEATED/IF NECESSARY/,FILTERED,DRAWN INTO THE DETECTOR CELL,WHERE IT PASSES THROUGH THE ELECTROLYTE SOLUTION. IF V OR G AGENTS ARE PRESENT,THE GALVANIC VOLTAGE PRODUCED BY THE CELL INCREASES. THE CHANGE IS AMPLIFIED BY THE ELECTRONIC MODULE WHICH SOUNDS THE DETECTOR HORN AND/OR ACTIVATED A FLASHING LIGHT,APPLIES POWER TO THE REMOTE TERMINALS AND STOPS THE PUMP MOTOR. THE HORN WILL CONTINUE TO SOUND AND/OR THE LIGHT FLASH UNTIL THE DETECTOR IS RESET OR DISCONNECTED GY THE OPERATOR. THE SYSTEM IS DESIGNED FOR MANPACK,FIXED EMPLACEMENT AND VEHICULAR USE. DRY CELL BATTERY IS USED FOR MANPACK APPLICATION. M10 POWER SUPPLY IS USED FOR FIXED EMPLACEMENT APPL. MOUNTING KIT AND INSTALLATION KIT ARE USED FOR 1/4 TON UTILITY TRUCK APPL. |
ALXZ | SPECIFIC USAGE DESIGN | SPECIFIC USAGE DESIGN SAMPLES AIR CONTINOUSLY,WHICH IS AUTOMATICALLY HEATED/IF NECESSARY/,FILTERED,DRAWN INTO THE DETECTOR CELL,WHERE IT PASSES THROUGH THE ELECTROLYTE SOLUTION. IF V OR G AGENTS ARE PRESENT,THE GALVANIC VOLTAGE PRODUCED BY THE CELL INCREASES. THE CHANGE IS AMPLIFIED BY THE ELECTRONIC MODULE WHICH SOUNDS THE DETECTOR HORN AND/OR ACTIVATED A FLASHING LIGHT,APPLIES POWER TO THE REMOTE TERMINALS AND STOPS THE PUMP MOTOR. THE HORN WILL CONTINUE TO SOUND AND/OR THE LIGHT FLASH UNTIL THE DETECTOR IS RESET OR DISCONNECTED GY THE OPERATOR. THE SYSTEM IS DESIGNED FOR MANPACK,FIXED EMPLACEMENT AND VEHICULAR USE. DRY CELL BATTERY IS USED FOR MANPACK APPLICATION. M10 POWER SUPPLY IS USED FOR FIXED EMPLACEMENT APPL. MOUNTING KIT AND INSTALLATION KIT ARE USED FOR 1/4 TON UTILITY TRUCK APPL. |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
APGF | DESIGN TYPE | NONTRIPOD MOUNTING |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
ACYR | DC VOLTAGE RATING | 28.0 VOLTS NOMINAL AND 28.0 VOLTS NOMINAL |
AMKD | INDICATOR TYPE | FLASHING RED LIGHT AND HORN |
ALBY | USAGE DESIGN | FIELD |
ALPC | COMPONENT AND QUANTITY | ALARM UNIT,CHEMICAL AGENT AUTOMATIC ALARM,M42,/FSN6665-859-2215/ 1! BATTERY,DRY /BA3517/,/FSN6135-450-3528/ 1! BATTERY,DRY /BA3202/,/FSN6135-935-8738/ 4! DETECTOR UNIT,CHEMICAL AGENT AUTOMATIC ALARM,M43,/FSN6665-859-2201/ 1! INSTALLATION KIT,CHEMICAL AGENT AUTOMATIC ALARM,FOR TRUCK,UTILITY 1/4 TON /FSN6665-479-2716/ 1! MOUNTING KIT,CHEMICAL AGENT AUTOMATIC ALARM,M228,HIGH PROFILE/FSN6665-859-2212/ 1! POWER SUPPLY,CHEMICAL AGENT AUTOMATIC ALARM,M10,/FSN6665-859-2225/ 1! REFILL KIT,CHEMICAL AGENT AUTOMATIC ALARM,M229,/FSN6665-859-2214/ 1 |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM |
FEAT | SPECIAL FEATURES | ALSO DETECTS V CHEMICAL AGENT ANDCAN BE USED ON VEHICLES |
BRQN | MEDIA DETECTED | G CHEMICAL AGENT |
FAAZ | PHASE | SINGLE |
ACUS | ALTERNATING CURRENT RATING IN AMPS | 1.5 |