Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
26522 | B G LABORATORIES INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.135 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.135 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAU | BODY HEIGHT | 2.750 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.230 INCHES MAXIMUM |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.485 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.515 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | BODY WIDTH | 2.500 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TAB, SOLDER LUG |
ABTD | MOUNTING SLOT WIDTH | 0.185 INCHES MINIMUM SINGLE GROUP AND 0.195 INCHES MAXIMUM SINGLE GROUP |