Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
39709 | MERCOID CORP THE |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABPM | BODY DIAMETER | 5.750 INCHES NOMINAL |
ABPM | BODY DIAMETER | 5.750 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.000 INCHES NOMINAL |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+75.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+75.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
AEVT | CAPILLARY TUBE LENGTH | 144.0 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | 120.0 DEG FAHRENHEIT MAXIMUM |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
ABKW | OVERALL HEIGHT | 2.125 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB AND EXTERNAL DEACTUATION POINT KNOB |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
ABHP | OVERALL LENGTH | 10.750 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE AND TUBING END SEAL CONNECTION |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL FOURTH VOLTAGE |