RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
99699 DRI RELAYS INC.

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AKDX WINDING QUANTITY 1
ABKW OVERALL HEIGHT 0.410 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 80.0 MILLIAMPERES DC SINGLE WINDING
ABMK OVERALL WIDTH 0.610 INCHES NOMINAL
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
APCN COIL QUANTITY 1
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
ABHP OVERALL LENGTH 0.810 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 300.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
APNA WINDING DC RESISTANCE RATING 140.0 OHMS NOMINAL SINGLE WINDING