Part Number
Definition:
AN OPEN OR INCLOSED FRAME STRUCTURE DESIGNED TO ACCOMMODATE (BUT DOES NOT INCLUDE) ELECTRICAL/ELECTRONIC EQUIPMENT MOUNTED ON STANDARD WIDTH PANELS SO THAT THE EQUIPMENT MAY BE OPERATED AFTER INSTALLATION WITHOUT BEING REMOVED. IT MUST HAVE PANEL MOUNTING RAILS THAT PROVIDE A UNIFORM PATTERN OF MOUNTING HOLES THAT WILL ACCOMMODATE VARIOUS COMBINATIONS OF STANDARD WIDTH PANELS. IT MAY INCLUDE WIRES, CABLES, TERMINAL BOARDS, CONNECTORS, AND THE LIKE, REQUIRED FOR EQUIPMENT OPERATION. SEE ALSO MOUNTING BASE, ELECTRICAL EQUIPMENT; CABINET, ELECTRICAL EQUIPMENT; AND CASE (2) (AS MODIFIED). EXCLUDES MAIN DISTRIBUTING FRAME, TELEPHONE AND INTERMEDIATE DISTRIBUTING FRAME, TELEPHONE.
CAGE Information
Code | Company |
---|---|
56772 | DA LO INDUSTRIES INC DIV DA LO INDUS |
Federal Supply Class
Title
ELECTRICAL HARDWARE AND SUPPLIES
Inclusions:
INCLUDES CONDUIT; RACEWAYS; FACE PLATES; CONDULETS; OUTLET AND JUNCTION BOXES; POLE LINE HARDWARE, NOT ELSEWHERE CLASSIFIABLE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEQK | PANEL SPACE HEIGHT | 36.750 INCHES NOMINAL |
ABFY | OVERALL DEPTH | 22.000 INCHES NOMINAL |
HUES | COLOR | BLACK |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
AEQT | PANEL RAIL THICKNESS | 0.109 INCHES NOMINAL |
AESP | PANEL WIDTH ACCOMMODATED | 17.875 INCHES NOMINAL |
AERD | PANEL MOUNTING RAIL HOLE ARRANGEMENT STYLE | ALTERNATIVE SPACING |
CRYK | PANEL MOUNTING RAIL HOLE TYPE | THREADED FRONT MOUNTING RAIL HOLE |
ABKW | OVERALL HEIGHT | 40.859 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 FRONT MOUNTING RAIL HOLE |
CBBL | FEATURES PROVIDED | KNOCKDOWN CONSTRUCTION |
MATT | MATERIAL | STEEL |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES FRONT MOUNTING RAIL HOLE |
AGAV | END ITEM IDENTIFICATION | AN/UGC-129(V)-1 TELETYPE |
AERU | HANDLING FACILITY TYPE | NONBRAKE TYPE CASTERS |
AERC | PANEL MOUNTING RAIL DESIGN STYLE | ANGLE |
THSD | THREAD SERIES DESIGNATOR | UNF FRONT MOUNTING RAIL HOLE |
STYL | STYLE DESIGNATOR | OPEN FRAME VERTICAL FRONT |