Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
CAGE Information
Code | Company |
---|---|
89326 | BARKSDALE INC |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 24.0 DC AT SEA LEVEL THIRD VOLTAGE |
CSCF | TERMINAL TYPE | SCREW |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.250 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL FIRST VOLTAGE |
ABKW | OVERALL HEIGHT | 4.562 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
ABMK | OVERALL WIDTH | 3.437 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.562 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTYM | CONTACT ADJUSTMENT RANGE | +4.00/+80.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.50/+76.50 DEACTUATION POINT POUNDS PER SQUARE INCH |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
ABHP | OVERALL LENGTH | 5.906 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |