Part Number
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
CAGE Information
Code | Company |
---|---|
71468 | ITT CORPORATION DBA I T T CANNON |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 2.012 INCHES NOMINAL |
PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.067 GOLD GRAINS, TROY |
PRMT | PRECIOUS MATERIAL | GOLD |
AFQW | MATING END QUANTITY | 1 |
CQTZ | CONTACT MATERIAL | COPPER ALLOY SINGLE MATING END ALL CONTACT GROUPINGS |
CXCG | INCLUDED CONTACT QUANTITY | 64 SINGLE MATING END 2ND CONTACT GROUPING |
ABHP | OVERALL LENGTH | 1.061 INCHES NOMINAL |
AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 0.060 INCHES NOMINAL |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END ALL CONTACT GROUPINGS |
CSWM | SHELL SURFACE TREATMENT | CADMIUM AND CHROMATE |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
AFRT | SHELL TYPE | SOLID |
AFQZ | CONTACT REMOVABILITY | REMOVABLE SINGLE MATING END ALL CONTACT GROUPINGS |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 7.5 SINGLE MATING END 2ND CONTACT GROUPING |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.715 INCHES MINIMUM AND 1.725 INCHES MAXIMUM |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | 67 SINGLE MATING END |
CXCL | INCLUDED CONTACT TYPE | ROUND PIN SINGLE MATING END ALL CONTACT GROUPINGS |
CSCF | TERMINAL TYPE | CRIMP SINGLE MATING END ALL CONTACT GROUPINGS |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.432 INCHES MINIMUM AND 1.442 INCHES MAXIMUM |
AFRC | CONTACT MAXIMUM CURRENT RATING IN AMPS | 13.0 SINGLE MATING END 1ST CONTACT GROUPING |
CSPT | SHELL MATERIAL | ALUMINUM ALLOY |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE PROOF AND SALT WATER RESISTANT AND VIBRATION RESISTANT |
CXCG | INCLUDED CONTACT QUANTITY | 3 SINGLE MATING END 1ST CONTACT GROUPING |
AAQL | BODY STYLE | STRAIGHT SHAPE, FLUSH MOUNT |
CQYH | CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END ALL CONTACT GROUPINGS AND COPPER SINGLE MATING END ALL CONTACT GROUPINGS |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |
CQZG | INSERT MATERIAL | PLASTIC DIALLYL PHTHALATE SINGLE MATING END |